AUF200 Series
Thông tin mô tả
Ultrasonic Flowmeter AUF200 Series - Bộ hiển thị lưu lượng theo nguyên lý siêu âm AUF200 Series
"Gọi 0974400989 để được tư vấn miễn phí"
Cam kết hàng mới 100%
Bảo hành chính hãng
- Mr. Hoàng Tấn
Hotline: 0974400989
Email: hoangtan@ame-engineering.com
- Ms. Ánh Tuyết
Hotline: 0948998638
Email: anhtuyet@ame-engineering.com
AUF200 Series measure flow or energy of water running in heating/cooling pipe by temperature sensor based on ultrasonic flowmeter. It's simple, easy to install and battery powered, no need of external power. It can display flow rate, total flow, total heat, total cool, heat power and supply/return temperature etc..
Features:
- Display flow rate, total flow, heating and cooling energy
- 3.6V battery power, continuous working for 6 years
- Auto turn off LCD if no operation within 3 minutes, saving power
- Supply or return alternatively for mounting
- Displayer 270o rotational
- Medium temperature up to 105 oC, DT 0-80 oC
- Threaded connection, easy for installation
- M-BUS communication, easy for remote control and reading
- Response time<15s
Specification:
Measuring Principle: | Velocity: | |
Ultrasonic, Time difference W path | 0.01 ~ 5 m/s | |
Size: | Connection: | |
15mm, 20mm, 25mm, 32mm, 40mm | Thread | |
Material: | Working Pressure: | |
Sensor | 25 Kg/cm2 Maximum | |
Stainless Steel 304 | Mounting Position: | |
Coupling | Supply or Return pipe | |
Brass | Displayer: | |
Ball Valve | Compact, 270o rotational | |
Brass | Ambient Temp.: | |
Display Housing |
|
|
PC | Ambient Humidity: | |
Turndown Ratio: | <=95% RH | |
50:1 ~100:1 | Power Supply: | |
Accuracy: | Battery Power | |
+/-2% Qt ~ Qmax | Battery Life: | |
Repeatability: | > 6 years (3800mA) | |
+/-0.3% of reading | Record Cycle: | |
Sensor Type: | 18 months | |
PT1000 2 wire, Class B | Record Data: | |
Medium Temp. Range: | Monthly Flow & Energy Totalizer | |
|
Communication: | |
Temp. Resolution: | M-BUS (optional) | |
|
Keyboard: | |
Temp. Difference: | One touch-control key (read only) | |
|
Response Time: | |
Temp. Error: | <15 Second | |
|
Dimensions: | |
Temp. Cable Length: | Page 3 | |
1.5m | Protection Class: | |
Display: | IP65 | |
2 lines, LCD | Communicator: | |
Temperature | M-BUS private communicator | |
|
Accessory: | |
Totalizer | Coupling x 1 Pair | |
M3, KW or GJ , Hour, 8 Digit | Ball Valve with temperature sensor hole | |
Flow Rate | M-BUS private communicator | |
M3/h, 4 digit | ||
Energy | ||
KW.h (Standard), GJ (Optional) | ||
Pressure Drop: | ||
Less than 0.2 Kg/cm2 (at Qn / Q3) |