Watanabe A6000 series
Description information
"Call 0974400989 for advice free call"
100% new commitment
Genuine warranty
- Mr. Hoàng Tấn
Hotline: 0974400989
Email: hoangtan@ame-engineering.com
- Ms. Ánh Tuyết
Hotline: 0948998638
Email: anhtuyet@ame-engineering.com
Đồng hồ đo đa năng Watanabe A6000 series
Watanabe Universal Digital Meter A6000 series
Tính năng (Features):
★ Standard 1/8 DIN size (48 x 96 mm).
★ Single display and multi display types are selectable.
★ Easy-to-use jog lever improves setup efficiency
★ Dual-color LED (red/green) visually indicates the alarm status.
★ The measurement range can be changed by switching the input range.
★ Max. 1 ms high sampling rate (Approx. 1000 times/sec)

Đặc điểm kỹ thuật chung (Common Specifications):
|
Display |
Main display : Red/Green 7-segment LED (20 mm height) Sub display : Red 7-segment LED (6 mm height) *Multi display type only Judgment display : HI / GO / LO *Relay/Photocoupler output type only Function display : RE / PH / DZ / TZ / ME / P1 / P2 / P3 |
|
Polarity |
'–' is displayed automatically at negative polarity |
|
Display range |
-9999 to 9999 |
|
Scaling |
Offset : ±9999, Full scale : ±9999 (Setting range) *Temperature input : Fixed scaling (cannot change) *Frequency input : Scale by Preset & division setting *Load cell input : Scale adjust by calibration setting |
|
Over range display |
Displays OVER or -OVER |
|
Decimal point |
Configurable *Temperature input is fixed per range |
|
Zero display |
Leading zero suppression |
|
Operating temperature and humidity range |
0 to +50°C, 35–85% RH (Non-condensing) |
|
Power supply |
1) AC power : 100–240 V AC ±10% 2) DC power : 12–48 V DC ±10% |
|
Power consumption |
1) AC power : 8 VA max. 2) DC power : 7 W max. |
|
Dimensions |
48(H)×96(W)×97.5(D) mm, 1/8 DIN size (*Without option) |
|
Weight |
Approx. 450 g |
|
Dielectric strength |
AC Power : Power to I/O terminal : 1500 V AC / 1 min DC Power : Power to I/O terminal : 500 V DC / 1 min Common: Input to Output terminal, between output terminal : 500 V DC / 1 min Case to Terminal : 1500 V AC / 1 min |
|
Insulation resistance |
100 MΩ or more at 500 V DC between the above terminals |
|
Sampling rate |
Approx. 1 ms to 5 s (Approx. 1000–0.2 times/s) *AC input : Approx. 400 ms to 5 s (2.5–0.2 times/s) *RTD input : Approx. 100 ms to 10 s (10–0.1 times/s) *TC input : Approx. 200 ms to 20 s (5–0.05 times/s) |
|
Moving average count |
Select from [ None / 2 / 4 / 8 / 16 / 32 ] |
|
Display update cycle |
Approx. 50 ms (20 times/s) *Frequency input : Approx. 100 ms (10 times/s) or more |
|
Sensor power supply |
Process input : 12 VDC ±10% 50 mA, or 24 VDC ±10% 25 mA Frequency input : 12 VDC ±10% 50 mA Load cell input : 5 VDC ±5% 30 mA, or 10 VDC ±5% 30 mA |
|
Standard accessories |
Unit sticker No.1, Terminal cover |
|
Optional accessories |
BCD output cable (A6BCDCN) |
Kích thước (Dimensions):