The Aliamag AMC2100E series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.AMC2100E series converter with temperature / energy.
Features:
- Four line LCD display Flow Rate / Energy / Totalizer
- Accuracy of +/-0.4% of reading
- Bi-directional flow measurement, current and pulse output
- Large digital display, with temperature / energy function
- 99 times records for power on / off
- MODBUS/HART communication
Specification:
Excitation: |
Keyboard: |
DC pulsed |
4 external keys for programming |
Display: |
and display control |
4 lines LCD with back light |
Low Flow Cutoff: |
Line 1 |
0 to 9.9 % |
Date and Time |
Data logger Function: |
Line 2 |
99times flowrate records for power on/off |
6 digit flowrate |
Record Data: |
7 digit energy value |
Date/Time when power on/off |
Fault code |
99 years flow rate / energy / |
Supply temperature |
temperature / total flow / total energy |
Line 3 |
One record data per Hour |
9 digit totalizer for forward / reverse flow |
Damping: |
9 digit totalizer for heat / cold energy |
0.1 to 99.9 seconds |
Fault code content |
Self Diagnosis: |
Return temperature |
The following error message are |
Line 4 |
displayed if failure occurs |
Differential temperature |
- Coil failure |
Unit |
- Power failure |
L/S, L/M, L/H, M3/S, M3/m, M3/H, ML/H, ML/m |
- Overanged Output |
ML/S, KW, MW, KJ/H, MJ/H, GJ/H, Mcal/H Kcal/H, Cal/H |
- Internal error |
Measuring Range: |
- Overflow |
Min. 0 to 0.15 m/s |
- Empty pipe |
Max. 0 to 15 m/s |
Cable Entry: |
Accuracy: |
Standard :PG11 Option:1/2"NPTF |
+/-0.4% of reading (Velocity >=0.5 m/s) |
Protection Class: |
+/-0.002 m/s (Velocity < 0.5 m/s) |
IP 65 |
Repeatability: |
Ambient Temperature: |
+/-0.1% of reading |
|
Current Output: |
Material: |
4-20 mA (Isolated) |
Aluminum Alloy |
Load |
Temperature Input: |
Max. 600 |
PT1000W, 2 wire |
Pulse output: |
Power Supply: |
Open collector |
90-260 VAC, 50/60 Hz |
Rating |
24 VDC +/- 10% (Option) |
3 to 30 VDC, 20 mA Max. |
Power Consumption: |
Pulse Rate: |
3-17 W (Dependent on sensor size) |
1)Scale pulse (Pusle/M3, Pulse/L, Other) |
Weight: |
2)Frequency: 0-5000 Hz |
1.4 Kg |
Communication: |
Mounting: |
RS 485 (MODBUS Protocol) |
Wall mounting |
HART signal (Compatible) |
Bracket on 2" pipe |
Data Storage: |
|
Operation parameters and totalizer |
|
figures are stored by EEPROM for more |
|
than 10 years |
|
|
|
|